汉堡
关闭
Search
路径
Home » Solutions » Solutions » What Size Walk-In Cooler Do I Need? A Guide for Restaurants And Small Food Businesses

What Size Walk-In Cooler Do I Need? A Guide for Restaurants And Small Food Businesses

What Size Walk-In Cooler Do I Need? A Guide for Restaurants and Small Food Businesses

It’s Friday morning. The weekend delivery arrives while Thursday’s stock is still on the shelves. Two cases end up in the aisle and the receiving cart can’t reach the back rack. Every time someone needs a tub of dough, they have to move something else first. The cooler looked big enough on the floor plan. On the busiest morning of the week, it’s already slowing the kitchen down.

Going up a size costs floor space. Going down can leave staff short of shelf space and turning room. Begin with the most stock you hold at one time, then lay out the shelves and walk through a delivery on the drawing.

How to size a walk-in cooler in three steps

1. Count stock on delivery day

Add the stock that normally remains before the next delivery to the largest incoming order. Group it by carton, crate or tray size. A shelf that holds three produce crates may hold only two deep ingredient tubs. Count usable shelf positions for each package type and allow room for busy weeks.

2. Draw the racks and the cart route

Request the clear interior length and width, then draw the shelves, the door opening, and the route for your largest cart. In a two-sided layout, subtract both shelf depths from the clear room width to estimate the aisle between the racks. Check protruding handles, the turning area by the door and the airflow clearances required by the equipment supplier.

Check the tightest point. A cart that fits in the center aisle still needs to pass through the door and reach the shelf without blocking the exit.

3. Match refrigeration to incoming stock

Once the layout works, give the refrigeration supplier the target temperature, the hottest expected conditions around the unit, how often the door opens, and the weight and temperature of incoming stock. Holding pre-chilled deliveries and cooling warm product are different duties, even in rooms with the same dimensions.

For refrigeration load calculations, see ASHRAE Handbook—Refrigeration, Chapter 16, “Food Service and General Commercial Refrigeration Equipment” and the International Institute of Refrigeration and Efficiency for Access guide Walk-In Cold Rooms: A Practitioner’s Technical Guide.

Two layouts for a 60-seat bistro

In this hypothetical example, a bistro receives pre-chilled produce and dairy twice a week. On Friday, 8 cases are still in storage when 13 more arrive. The manager needs 21 shelf positions at once. Most cases measure about 400 × 300 mm (16 × 12 in), and the receiving cart is 560 mm (22 in) wide.

The manager allows three case positions per shelf. Each rack is 1.2 m long and 450 mm deep, with the 400 mm side of each case running front to back. Two racks with four usable levels each give the kitchen 24 positions in all.

Cases at peak Shelf positions Spare positions
21 24 3

2 racks × 4 levels × 3 cases per level = 24 shelf positions

How much room does a 560 mm cart leave?
Dimension Compact layout Wider layout
Clear inside dimensions 2.2 × 1.5 m 2.8 × 1.8 m
Shelf depth on each side 450 mm 450 mm
Aisle between racks 600 mm 900 mm
Total clearance around cart 40 mm 340 mm

Both sketches fit the two racks. The compact layout leaves only 40 mm (about 1.6 in) of total clearance around the cart between the racks. The wider layout is the better one to draw up first. The door, turns and site requirements still need checking. If the bistro must use the compact footprint, a one-sided layout is worth testing with the actual cart and case mix.

Could a 3 m FLAND modular cooler fit this kitchen?

For a kitchen like this bistro, the FLAND modular cold room with monoblock refrigeration has a nominal 3 × 2 × 2.2 m footprint and height (about 10 × 6.6 × 7.2 ft, L × W × H). Use the exterior dimensions to check the space available in the building. Use the quoted clear interior, door opening and equipment projection to confirm how the room will work with both racks installed.

The modular panel enclosure and matched refrigeration package suit a small kitchen moving its bulk stock out of individual cabinets. In this case, the deciding detail is the aisle across from the two racks. Once a layout offers enough working clearance, the temperature, receiving schedule and site conditions can be used to select the refrigeration configuration.

Have FLAND check your layout

Send your available floor space, peak case count, largest cart width and target storage temperature. Include a sketch of the door and shelves if you have one.

Request a layout review  →

  • FLAND COLD STORAGE HEART EVERY TIME
  • get ready for the future
    sign up for our newsletter to get updates straight to your inbox